Electricity consumption and production in the Triangle Area

27. Jan. 2023

 

This dataset contains electricity consumption (and production) per quarter-hour per electricity meter from TREFOR electricity grid.

Geographical location: Triangle Region of Denmark

Author: Center Denmark (https://www.centerdenmark.com/)

Data source: TREFOR El-net (https://www.trefor.dk/elnet/)

Number of unique meter ID: > 130.000

Data sensitivy: Raw

 

Click to request access to the dataset

 

Notes:

  • Date and time format for the datasets follows the ISO 8601 standard.
  • A validation rule contains a formula or expression that evaluates the data in one or more fields and returns a value of true or false

 

Electricity consumption and production in the Triangle Area

General information

 

Name

ElectricityConsumptionTriangle

Unique Key

installation_id, meter_id

Time Column timestamp
Resolution PT15M
Update Frequency P1D
Dataset Published  
Data From 2021-01-01

 

Timestamp

 

Name timestamp
Description A date and time are shown in UTC.
Comment Timestamp column is representing the date and time in ISO 8601 format: YYYY-MM-DDTHH:MM:SS.
Data Type Timestamp
Unit  
Example 2021-12-01T00:00:00
Validation Rule Always represented in full quarter-hours, i.e., minutes are either 00, 15, 30 or 45.

 

Product component

 

Name product_component
Description Value to identifity if it is active-, or reactive power consumption and production.
Comment The Product Component column is a categorical value. The Product Component column has a cardinality of 4 and contains the following categories: 1, 2, 3, 4 (active power consumption, active power production, reactive power consumption, reactive power production).
Data Type integer
Unit  
Example 1
Validation Rule  ∈ {1, 2, 3, 4}

 

Value

 

Name value
Description Electricity meter measurement values.
Comment Measurement units are based on the Product Component column.
Data Type decimal
Unit

Measurement units are based on the Product Component column:

 

  • 1 is active power consumption (kWh)
  • 2 is active power production (kWh)
  • 3 is reactive power consumption (kVARh)
  • 4 is reactive power production (kVARh)
Example 0.06
Validation Rule  

 

Installation ID

 

Name installation_id
Description The installation number follows the installation address.
Comment  
Data Type string
Unit  
Example 1204421
Validation Rule  

 

Meter ID

 

Name meter_id
Description The meter number identifies individual meters.
Comment  
Data Type string
Unit  
Example 61029547
Validation Rule